Leak detection & repairs · Edgware

Leak detection in Edgware: is the heating losing water or is it a plumbing leak?

A damp patch or a falling boiler pressure can come from two quite different sources. One is the heating circuit, which is sealed and should lose almost nothing. The other is the plumbing that feeds taps, showers and appliances. A short test with the gauge and the meter separates them. Households in Edgware can run it in a quarter of an hour and send the engineer a clear starting point, which saves a visit and, often, an argument about whether the fault is a heating one or a plumbing one.

Certified for the work. Heat Go holds Gas Safe, WaterSafe, G3 and heating and plumbing certification. Call +44 7551 336264 to talk it through.

Gas Safe Register WaterSafe Heat Go G3 certified Heat Go Heating and Plumbing Engineer

Edgware’s Tube station, which opened on 18 August 1924 as the terminus of the extension, anchors a district of houses and flats with heating of many ages. Radiators, pipes and valves in the heating circuit can weep at joints, and so can the pipes behind sinks and baths. The symptoms overlap, which is why a short test is worth running.

The method has three parts. Read the boiler pressure gauge when cold, and again a day later, noting any fall. A circuit that falls steadily is losing water, and a note of the rate helps the engineer judge how big the leak is. Read the water meter with every tap and appliance off, watching for movement. If the meter moves, plumbing is leaking. Look at radiator valves, joints and the boiler for damp, and check under sinks and baths. Photograph any damp spot, with the date. If pressure falls and the meter is still, the heating circuit is the likelier culprit, and the boiler’s own manual explains how to restore the pressure safely.

Your pressure readings, meter observations and photographs of any damp let Heat Go read the results with you.

Telling a heating leak from a plumbing leak in an Edgware home

Leak sources in different Edgware homes

Homes full of radiators

Each valve and joint is a possible weep, so check each, starting with the oldest.

Flats with a combi boiler

The pressure gauge is on the boiler. Read it regularly and note any fall.

Homes heated through the floor

Pipes under the floor cannot be seen, and a steady loss of pressure may point to them.

SettingParking and van accessProperty accessTypical enquiries
Homes full of radiatorsRoadsideHallwayRadiator joints
Flats with a combi boilerPermit zonesKitchenCombi pressure
Homes heated through the floorDrives commonGround floorHidden pipes

Say where the boiler and gauge are, and where any damp has appeared. Photographs of the gauge, with dates, help the engineer.

A householder finds that her boiler pressure drops from 1.3 to 0.7 bar over a week. She reads the meter with everything off and it stays still. She looks at the radiators and sees a faint green mark on a valve in the back bedroom. She photographs it and sends the readings. The reply suggests the valve gland as the likely leak, and that the circuit be re-pressurised after the repair.

Heating circuits are tested when the heating returns in autumn. A pressure log from September shows a slow loss before the cold arrives.

Good to know in Edgware

Sealed circuit

A closed heating system that should hold its pressure with little or no loss.

Pressure drop

A fall in the gauge reading, which shows water has escaped from the circuit.

Valve gland

The seal around a radiator valve’s spindle. It can weep when it wears.

Questions about leak detection & repairs in Edgware

01Why does my boiler pressure keep falling?

Water is escaping from the heating circuit, from a valve, a joint or an unseen pipe, and the quicker the fall, the sooner it needs looking at.

02How do I tell it from a plumbing leak?

A moving meter with everything off points to plumbing. A steady pressure drop with a still meter points to heating.

03Can I top up the pressure?

Often, as the manual describes, and many boilers have a filling loop for it. If it keeps falling, report it, because repeated top-ups can hide a leak.

04Is a green mark on a valve a leak?

It suggests a slow weep, where copper corrodes in the damp. Photograph it, note the date and report it, since the valve will probably need a new gland or replacement.

05Does the pressure matter to the boiler?

Yes. Too low and it will lock out, leaving the house without heat or hot water until the pressure is restored, which is another reason to find the leak.

Talk to Heat Go

Ask about leak detection & repairs in Edgware.

Heat Go can say which circuit is leaking if it has your readings, your photographs and your Edgware street.

The quickest way to talk to a Gas Safe, WaterSafe and G3 certified team is to call +44 7551 336264.

Leak detection & repairs enquiry