Finsbury Park houses with a long pipe run to a rear unit
More pipe needs more refrigerant. Ask for the extra to be worked out.
Refrigerant-related work · Finsbury Park
It is natural to think that a little more or less refrigerant makes little difference. In fact, a system is built for a stated amount, and being short or over-filled both reduce its cooling and strain its parts. The engineer should add what the system needs and note it. A record of the amount helps every later visit. Households in Finsbury Park can ask for the figure to be written down.
Certified for the work. Heat Go holds Gas Safe, WaterSafe, G3 and heating and plumbing certification. Call +44 7551 336264 to talk it through.
Larger houses in Finsbury Park often have long pipe runs between the indoor and outdoor units, and the right amount depends on the length. A unit fitted with extra pipe needs extra refrigerant. Without a record, a later engineer can only guess what the system holds.
Five points help. The maker states a factory charge for the outdoor unit and a rule for extra charge per metre of pipe beyond a stated length. The engineer measures the pipe run and works out the total amount. He weighs the refrigerant as it goes in, using scales, not guessing by gauge alone. He records the amount added, the pipe length and the date. And he checks the running pressures and temperatures afterwards. Ask him to write the charge in the record and give you a copy. If a later visit adds refrigerant, the record should show the new total, and why it was needed, since a sealed system should not lose refrigerant.
A short record sheet, with boxes for pipe length, factory charge, extra charge and date, comes from Heat Go when you share the unit’s make.
More pipe needs more refrigerant. Ask for the extra to be worked out.
The run changed. Ask for the charge to be rechecked.
The charge is unknown. Ask the engineer to note it now.
| Setting | Parking and van access | Property access | Typical enquiries |
|---|---|---|---|
| Finsbury Park houses with a long pipe run to a rear unit | Roadside | Rear room | Long runs |
| Finsbury Park homes where the unit was moved | Drives common | Garden | Moved units |
| Finsbury Park houses where the record is missing | Permit zones | Study | Missing records |
Let the engineer see the unit’s label and the maker’s guide, and lead him along the pipe route yourself. Mention whether anyone has ever added refrigerant.
A large Finsbury Park house has its unit moved to a new wall, which lengthens the pipe run. The engineer measures the new run, finds it exceeds the factory length, and works out the extra charge from the maker’s rule. He weighs the refrigerant, adds it and checks the running pressures. He writes the factory charge, the extra charge, the pipe length and the date in the record. The household keeps the record with the manual. At a later service, the engineer reads it and knows what the system should hold. At a later service, the engineer reads the record, compares the running pressures with the stated charge and finds them in range. He adds a line to the record with the date. The household sees that a clear record turns a service into a check against a known figure, and keeps the page at the front of the folder.
A charge is set at installation or a move, which often happens in spring. The record is then used at every service. A system that loses refrigerant over time has a leak, and the record shows when the total changed. A charge is set when a unit is installed or moved, which often happens in spring. The record is then used at each yearly service. A system that needs a top-up has lost refrigerant somewhere, so the record also shows when a leak began.
The amount of refrigerant a maker puts in an outdoor unit before it leaves the factory.
Additional refrigerant needed for pipe longer than the factory length.
The pressure in the refrigerant circuit while the unit is working.
Yes, too little or too much harms performance.
By weight, as it goes in.
Yes, with the pipe length and date.
Ask why, since a sealed system should not lose refrigerant.
Dial 0800 111 999 first, while Finsbury Park refrigerant work can wait: leave, and Finsbury Park refrigerant work may resume later.
Talk to Heat Go
Heat Go can prepare a charge record sheet, one box per figure, from the make you pass on.
The quickest way to talk to a Gas Safe, WaterSafe and G3 certified team is to call +44 7551 336264.
All air conditioning servicesEvery service in Finsbury ParkAll refrigerant-related work areas