Highgate houses where a bedroom became a study
The unit may stay. Ask whether it is still suited to the new use.
Refrigerant-related work · Highgate
In a multi-split system, one outdoor unit serves several rooms. If one room no longer needs cooling, perhaps after a conversion, the indoor unit can be removed. The pipe that fed it cannot simply be left open. It has to be sealed and recorded, and the rest of the system must be checked afterwards. Highgate households with a multi-room system can ask how the spare connection will be handled.
Certified for the work. Heat Go holds Gas Safe, WaterSafe, G3 and heating and plumbing certification. Call +44 7551 336264 to talk it through.
Larger houses in Highgate change use over time, with a bedroom becoming a study or an extension absorbing a room. A unit that was fitted for one purpose may no longer fit the room. The pipes lead through lofts and voids, so removing the unit also means dealing with a length of pipe that may stay in place.
Five steps are involved. The refrigerant in the part of the system to be removed is recovered into a proper cylinder, not released. The indoor unit is disconnected and taken away. The pipe that fed it is sealed at the connection, with a cap or a brazed seal, and tested to show it holds. The remaining rooms are checked to be sure they work correctly, with the outdoor unit’s settings adjusted if needed. And the record is updated, with a marked-up diagram showing which room was removed and how. Ask the engineer to describe each step and to leave the diagram. A sealed spur left in a void should be labelled.
Heat Go can draw up a short list of questions about removing a room from a system if you tell it which room and how the pipes run.
The unit may stay. Ask whether it is still suited to the new use.
The unit may need moving. Ask whether it can be re-fitted in the new space.
A spare pipe may remain. Ask for it to be labelled.
| Setting | Parking and van access | Property access | Typical enquiries |
|---|---|---|---|
| Highgate houses where a bedroom became a study | Roadside | Study | Changed use |
| Highgate houses with an extension absorbing a room | Drives common | Extension | Extensions |
| Highgate houses with pipes through a loft void | Permit zones | Loft | Spare spurs |
Give the engineer the system diagram and tell him which room is changing. Say whether the unit is to be reused or scrapped.
A Highgate household converts a spare bedroom into a walk-in wardrobe and decides to take the indoor unit out of the system. The engineer recovers the refrigerant from that part of the pipework, removes the indoor unit and seals the spare pipe with a brazed cap. He tests the seal, checks the other two rooms and adjusts the outdoor settings. He updates the diagram, marks the sealed spur and writes the change in the record. The household keeps the diagram with the house papers, so a later owner can see what happened. A year later, a new owner of the house reads the diagram and the record and sees at once that the guest room’s unit was removed and its pipe sealed. The sealed spur is labelled in the loft, and nobody mistakes it for a live pipe. The household had asked the engineer to label it for exactly this reason. The updated diagram saves a long search when another unit is later serviced.
Removal is easiest before the cooling season, when the system is idle and the engineer has time. In summer, the remaining units are in demand, and taking one offline for a day is harder to arrange. A change made in March is ready for use by June. Taking a room out of a system is best done in spring or autumn, when the units are idle and the engineer has time. In summer, every working room is needed. A label on the spur is a small step that helps every later visit.
The removal of refrigerant from a system into a cylinder so that it is not released to the air.
A metal cap joined to a pipe end by high-temperature soldering to seal it.
A short length of pipe left sealed after the unit it fed has been removed.
Yes, with the pipe sealed and tested.
It should be recovered, not released.
Yes, ask for them to be tested.
Yes, with the change marked.
Phone 0800 111 999 first; since Highgate refrigerant work is not started, and Highgate refrigerant work carries on later.
Talk to Heat Go
Tell Heat Go which room is changing and how the pipes run, and a few questions for the engineer will be drafted.
The quickest way to talk to a Gas Safe, WaterSafe and G3 certified team is to call +44 7551 336264.