Homes with a combi boiler
A diverter valve switches the boiler between heating and hot water. If it sticks, one function stops.
Boiler repairs · Barnet
When a boiler produces hot water but no heating, or heating but no hot water, the fault is usually narrow, and the symptom points to it. Parts that serve one function but not the other include a diverter valve, a motorised valve, a pump, a thermostat and a programmer setting. Knowing which is which saves a great deal of guessing. People in Barnet can work out the likely cause with a few observations.
Certified for the work. Heat Go holds Gas Safe, WaterSafe, G3 and heating and plumbing certification. Call +44 7551 336264 to talk it through.
Barnet’s houses and flats, many near the High Barnet terminus that has stood since 1872, contain a mixture of combi boilers and systems with cylinders. The two behave differently when one function fails. A combi uses a diverter valve to switch between heating and hot water. A system with a cylinder uses motorised valves. Which type you have decides which parts to suspect.
For a combi, the usual suspects are the diverter valve, which may be stuck in one position, and the heat exchanger, which can scale. If the hot water works and the heating does not, the pump or a heating thermostat may be at fault. For a system boiler with a cylinder, a stuck zone valve is common. A programmer or thermostat set wrongly can also mimic these faults. A note of which function fails, plus the boiler type, narrows the field a great deal, and an engineer can often bring the right part on the first visit.
The most helpful thing to send is an exact description of what works and what does not. Heat Go can then say which part is likely and what a visit would bring. Should gas be noticed at any point, abandon this page, step outside and phone 0800 111 999 straight away.
A diverter valve switches the boiler between heating and hot water. If it sticks, one function stops.
Motorised valves direct water to the cylinder or the radiators. A stuck valve leaves one cold.
A small cupboard can hide a fault. Photograph the boiler and note which function fails.
| Setting | Parking and van access | Property access | Typical enquiries |
|---|---|---|---|
| Homes with a combi boiler | Roadside | Kitchen | Diverter valves |
| Homes with a cylinder | Drives common | Airing cupboard | Motorised valves |
| Flats with a combi in a cupboard | Permit zones | Landing | Cupboard boilers |
Show where the boiler stands, and whether the cylinder or the valves live in another cupboard. A word on parking near the house helps the visit start promptly.
A household find that the shower is hot but the radiators are cold. They check the programmer and thermostat, which are set correctly. They feel the pipes and find the heating flow is cold. They note that the boiler fires for hot water but not for heating, and that it is a combi. A reply from Heat Go can suggest that the pump or a heating circuit fault is likely, and what an engineer would test.
Heating faults show up when the heating is needed. A short test in September, running both functions, can reveal a sticky valve before the cold weather.
Switches a combi between heating and hot water. It can stick or wear.
Directs hot water to the cylinder or radiators. It can stick or fail.
The part that heats water. Scale can reduce its output.
A diverter valve, a scaled heat exchanger or a valve on the cylinder side may be at fault, and the boiler type points to which.
A pump, a heating thermostat, a zone valve or a blocked circuit are common causes, and a hot pipe at the boiler with cold radiators suggests the pump.
Yes. Check the settings first, including the hot water channel, since a single changed setting can mimic a broken part.
It is not usually dangerous, but a boiler that behaves oddly should be checked, particularly before the colder weather asks more of it.
Yes: a smell of gas. Get out, touch no switches, and once clear of the building phone the free line, 0800 111 999.
Gas emergency
If you suspect a gas leak, call the National Gas Emergency Service immediately on 0800 111 999. The enquiry form below is for non-emergency questions.
Talk to Heat Go
Tell Heat Go which function has failed, what type of boiler you have and which Barnet road you live on, and a likely part can be suggested. Anything that smells of gas is a 0800 111 999 matter, never a form one.
The quickest way to talk to a Gas Safe, WaterSafe and G3 certified team is to call +44 7551 336264.
All boiler servicesEvery service in BarnetAll boiler repairs areas