Whetstone houses where upstairs rooms stay cool in cold snaps
The curve may be too low at low outside temperatures. Ask about a step up.
Heat pump controls & optimisation · Whetstone
A heat pump runs best when it sends out only as warm a flow as the weather demands. A setting called the weather compensation curve does that job: it raises the flow temperature when it is cold outside and lowers it when it is mild. If the curve is set too high the system wastes effort. If too low, rooms stay cool. A household that understands the idea can ask for a review. A Whetstone household can read this once the first winter with the heat pump is over.
Certified for the work. Heat Go holds Gas Safe, WaterSafe, G3 and heating and plumbing certification. Call +44 7551 336264 to talk it through.
Houses in Whetstone with heat pumps have a controller with an outside sensor, and the curve is set at commissioning to suit the design. After a winter of living in the house, the household knows which rooms are comfortable and which are not. That knowledge is the best input for a review.
The idea is simple. The controller reads the outside temperature and picks a flow temperature from the curve. A steeper curve means a warmer flow for each degree of cold. A flatter curve means a gentler one. A review looks at how the rooms felt on cold, mild and very cold days and moves the curve a step or two. Ask the engineer to explain the present setting and why it was chosen. Ask what a change would do and how long to wait before judging it. Write down each adjustment with its date, and leave at least a week before judging it. Do not alter the curve yourself unless the booklet explains and you are confident, because a hasty change can leave rooms cold.
Heat Go can work with you to prepare. Tell us how the rooms felt, and a short note for the review visit can be written.
The curve may be too low at low outside temperatures. Ask about a step up.
The curve may be too high in the mild range. Ask about a step down.
For heat pump controls in Whetstone, the floors respond slowly. Ask about a lower, flatter curve.
| Setting | Parking and van access | Property access | Typical enquiries |
|---|---|---|---|
| Whetstone houses where upstairs rooms stay cool in cold snaps | Roadside | Bedroom | Cold snaps |
| Whetstone houses where rooms feel too warm in mild weather | Drives common | Living room | Mild weather |
| Whetstone houses with underfloor heating on the ground floor | Permit zones | Kitchen | Slow floors |
Give the engineer your note of how each room felt on cold, mild and very cold days and ask for the curve to be reviewed.
A household in a semi-detached house finishes its first winter with a heat pump. The ground floor was comfortable, the bedrooms cool on the coldest days and the living room slightly too warm in March. They write a note of each. At the review the engineer reads it, explains the present curve and says it was chosen to be cautious. He raises the curve one step in the cold range and lowers it one step in the mild range, writes both on the record and asks them to wait a fortnight. They note the effect on a page, and on the next cold day the bedrooms are comfortable and the living room is not overheated. The household files the page with the record.
A review after a first winter, in spring, uses a whole season of experience, and any change can be tested through the mild weather before next winter.
A control method that adjusts the heat pump’s flow temperature to match the outside temperature.
The line on a controller that links outside temperature to flow temperature.
A small device on an outside wall that reports the outdoor temperature to the controller.
A setting that adjusts the flow temperature to the weather.
Only if the booklet explains and you are confident.
At least a week, ideally a fortnight.
A season of living in the house shows what to adjust.
Leave the Whetstone building at once, before any heat pump controls step, ring 0800 111 999, Whetstone switches and flames stay off limits.
Talk to Heat Go
Tell Heat Go how the rooms felt in your Whetstone house over winter, and a note for the review visit can be written.
The quickest way to talk to a Gas Safe, WaterSafe and G3 certified team is to call +44 7551 336264.
All heat pumps servicesEvery service in WhetstoneAll heat pump controls & optimisation areas