Houses with the meter at the front and the boiler at the back
The run is long. Ask for the pipe size to be checked at the meter and at the boiler.
Boiler installation · Whetstone
A new boiler may need more gas than the old one, or the same amount delivered more reliably. The pipe that brings the gas from the meter was sized for an earlier appliance, and it may be narrow, long or shared with a cooker and a fire. If the pipe is too small, the boiler may struggle to fire at full output on a cold day. A short check at the survey stage avoids a disappointing first winter. Anyone in Whetstone with a long pipe run can ask for it.
Certified for the work. Heat Go holds Gas Safe, WaterSafe, G3 and heating and plumbing certification. Call +44 7551 336264 to talk it through.
Many houses in Whetstone have the meter at the front and the boiler at the back, with a gas pipe running the length of the house, often in a ceiling void or under a floor. Over the years, a cooker, a fire or a second boiler may have been added to the same pipe. The installer should look at the route, the size of the pipe, the number of appliances it serves and the meter’s capacity.
Five things make up the check. The boiler’s gas rate, from the maker’s data. The size of the pipe at the meter and along the run, noted at each change. The length of the run and the number of bends. The other appliances on the same supply and the rate each draws. And a test of the gas pressure at the boiler, with the boiler and other appliances running together, to show that it does not fall. If the pipe is too small, a larger one can be run on a new route. A written note should record the readings, noting the date and who took them, so that anyone who later adds an appliance can compare.
Heat Go can help you plan the check. Describe where the meter and the boiler are and what else burns gas, and a short question sheet for the installer can be written.
The run is long. Ask for the pipe size to be checked at the meter and at the boiler.
Each draws gas at once. Ask for a pressure test with all running together.
A larger pipe is hard to run. Ask about alternative routes.
| Setting | Parking and van access | Property access | Typical enquiries |
|---|---|---|---|
| Houses with the meter at the front and the boiler at the back | Roadside | Hallway | Long runs |
| Houses with a gas fire and a cooker on the same pipe | Drives common | Kitchen | Shared supplies |
| Houses with pipes under a solid floor | Permit zones | Utility room | Buried pipes |
Tell the installer which appliances use gas and where the pipes run. Show them the meter and any plan of the pipework.
A household in a long house plans a larger boiler. The installer finds the gas pipe narrows along the run and serves a cooker and a fire as well. He tests the pressure at the boiler with the cooker running and sees it fall. He proposes a new, wider pipe on a route through the ceiling void. After the work, the pressure holds with everything on. The household keeps his readings and a sketch of the new pipe’s route, and later passes both to the next owner when the house is sold, so the history of the supply is not lost.
A gas pipe check belongs in the survey. Late summer is a good time to ask, with the work done before the cold. A pipe that is marginal in October can be a real problem in January, when the boiler runs flat out for hours and other gas appliances run beside it at the same time.
How much fuel a gas appliance burns when working at full output, normally quoted in kilowatts.
The gas pressure at an appliance while it is running.
The length of pipe between the meter and an appliance, including each bend along the way.
A narrow pipe may starve a boiler on a cold day.
By measuring the pipe and testing pressure with appliances running.
Often, on a new route.
The installer, with a gauge.
If you can smell gas, 0800 111 999 is the number to call first, from outside, with the windows open and no switch or flame used.
Gas emergency
If you suspect a gas leak, call the National Gas Emergency Service immediately on 0800 111 999. The enquiry form below is for non-emergency questions.
Talk to Heat Go
Tell Heat Go where your meter and boiler are, naming your Whetstone street, and a question sheet for the installer can be written.
The quickest way to talk to a Gas Safe, WaterSafe and G3 certified team is to call +44 7551 336264.
All boiler servicesEvery service in WhetstoneAll boiler installation areas