Homes with fifteen millimetre pipes to radiators
Small bore limits flow. Ask which radiators may need larger branches.
Heat pump system assessment · Hendon
A heat pump heats water to a lower temperature than a boiler, so it must move more of it to deliver the same warmth. Pipes that suited a boiler may be too narrow for that larger flow. The result is noise, poor heat in the far rooms and a pump that works harder than it should. An assessment that measures the pipework, not just the radiators, finds the problem early. Residents in Hendon can ask for it to be included.
Certified for the work. Heat Go holds Gas Safe, WaterSafe, G3 and heating and plumbing certification. Call +44 7551 336264 to talk it through.
Homes near Hendon Central often have heating pipework of fifteen or twenty-two millimetre copper, fitted decades ago, with branches of small bore to individual radiators. A boiler can push hot water through narrow pipes quickly. A heat pump cannot do so without a high pump speed, which adds noise and uses electricity. Long runs and many bends make it worse.
An assessment of pipework covers five points. The size of the main pipes and the branches, measured or read from markings. The length of the longest runs and the number of fittings. The flow rate each radiator needs at the lower temperature, calculated from its heat output. The pump’s capacity and speed settings. And the likely noise at the proposed flow. If the pipes are too small, the engineer can suggest which sections to replace, and which can stay. A written summary lists each finding.
Heat Go can help you read an assessment. Send the summary, hiding any personal details, and a straightforward reading can be offered.
Small bore limits flow. Ask which radiators may need larger branches.
Distance adds resistance. Ask about the farthest radiators first.
Each bend adds resistance. Ask whether the route can be simplified.
| Setting | Parking and van access | Property access | Typical enquiries |
|---|---|---|---|
| Homes with fifteen millimetre pipes to radiators | Permit zones | Hallway | Narrow branches |
| Flats with long runs from a hall cupboard | Roadside | Living room | Long runs |
| Homes with many bends in the pipes | Drives common | Kitchen | Bends |
Give the assessor access to the pipes in lofts, cupboards and under floors. Tell them about any past noise or cold radiators.
A household in an older house has the pipework assessed for a heat pump. The assessor measures the main run and finds it is twenty-two millimetre, with fifteen millimetre branches. Two far radiators need larger branches at the low temperature. He lists them and the lengths, and estimates the pump speed and noise. The household decides to replace the two branches when the pump is fitted. His summary goes in the folder. The assessor explains that replacing a branch is cheap and quick when it is done while a pump is being fitted, because the radiator is already drained and the floor is already up. He also notes that two other branches, though small, are short and carry little heat, so they can stay. The household appreciates having the reasoning on paper, and writes the lengths and sizes on a sketch that goes into the folder with the summary. When the plumber arrives, he works from the sketch and finishes the two branches in an afternoon, and the radiators in the far rooms warm evenly in the first week of use. The assessor leaves a note of the new branch sizes and lengths for the logbook, so that a later engineer need not measure them again.
An assessment is best made in summer, so that pipework can be changed before the heating season begins.
A smaller pipe taking water off the main run to serve one radiator.
How much water passes along a pipe in a set period.
The inside diameter of a pipe, which limits how much water can pass.
Often, because they move more water at a lower temperature.
Sometimes, if the flow they need is within their capacity.
Noise, poor heat in far rooms and a harder-working pump.
The assessor, at the survey.
Each finding and each section that should change.
Talk to Heat Go
Pass Heat Go the assessor’s summary together with your Hendon road, and a clear reading of it can be offered.
The quickest way to talk to a Gas Safe, WaterSafe and G3 certified team is to call +44 7551 336264.
All heat pumps servicesEvery service in HendonAll heat pump system assessment areas