Heat pump servicing · Highgate

Heat pump servicing in Highgate: checking the expansion vessel and pressure on a larger system with a big cylinder and long pipe runs

A big house means a big volume of water in the heating circuit, and water expands as it warms. A sealed circuit copes with this through an expansion vessel, a small tank with a cushion of air or gas. If the vessel loses its charge, the pressure swings, and the pressure relief valve may open. Highgate households with larger systems can ask for the vessel to be checked at each service.

Certified for the work. Heat Go holds Gas Safe, WaterSafe, G3 and heating and plumbing certification. Call +44 7551 336264 to talk it through.

Gas Safe Register WaterSafe Heat Go G3 certified Heat Go Heating and Plumbing Engineer

Big Highgate houses have long pipe runs, several zones and large cylinders. The extra volume puts more work on the expansion vessels, which may be fitted on the heating circuit and the hot water. They are often tucked in a plant room or a cupboard, and nobody looks at them from one year to the next.

Five points make up the check. The engineer notes the pressure on the gauge with the system cold and again when warm, to see how much it rises. He checks the charge in each expansion vessel with a gauge on its valve, and recharges if needed. He looks at the pressure relief valve and its discharge pipe for signs of weeping. He checks the filling loop and the top-up record, to see how often the system has needed water. And he notes the readings in the service record. A system that needs frequent topping up has a leak somewhere, and a vessel that has lost its charge shows as a large pressure swing.

Heat Go can draw up a short pressure and vessel question list for the engineer if you tell it how many zones and cylinders the house has.

Checking the expansion vessel and pressure on a large heat pump system in a Highgate house

Vessel and pressure questions in Highgate houses

Highgate houses with two cylinders and several zones

There may be several vessels. Ask the engineer to find and test each.

Highgate houses where the pressure falls over weeks

A leak or a vessel fault may be the cause. Ask for both to be checked.

Highgate houses where the relief pipe drips

The pressure may be too high. Ask for the vessel charge to be tested.

SettingParking and van accessProperty accessTypical enquiries
Highgate houses with two cylinders and several zonesRoadsidePlant roomMany vessels
Highgate houses where the pressure falls over weeksDrives commonUtility roomFalling pressure
Highgate houses where the relief pipe dripsPermit zonesOutside wallDripping valves

Show the engineer the plant room, the gauge and the relief pipe outlet. Tell him if the pressure has needed topping up and how often.

A Highgate household with a large heat pump system notices that the pressure gauge rises sharply when the system warms. They note the cold and warm readings and tell the engineer, who finds the heating expansion vessel has lost most of its charge. He recharges it, checks the second vessel and tests the relief valve. The pressure now stays within a narrow band. He writes the values in the service record and shows the household where each vessel is. The note goes in the plant room folder for the next engineer. The household adds the readings to a one-page chart and pins it in the plant room, so that the pressure can be compared at each visit. They also note the date the vessels were last checked and set a reminder for the next. A visiting plumber later reads the chart and finds the work much simpler for having the figures to hand.

A pressure check suits late summer, before the heating season and with the system idle. Winter pressure swings put the relief valve to work, so a check beforehand prevents leaks and a cold house. A household that notes the gauge monthly can spot a drift early.

Good to know in Highgate

Expansion vessel

A small tank with a flexible diaphragm that absorbs the growth of heating water as it warms.

Charge

The pressure of air or gas on the dry side of an expansion vessel’s diaphragm.

Relief valve

A safety valve that opens to release pressure if it becomes too high.

Questions about heat pump servicing in Highgate

01In Highgate, what does an expansion vessel do?

It absorbs the growth of water as it heats.

02In Highgate, why does pressure swing?

The vessel may have lost its charge.

03In Highgate, should I top up myself?

Only as the maker’s guide shows, and note the reading.

04In Highgate, what if the relief valve drips?

Ask the engineer to check the vessel and pressure.

05How does Highgate heat pump servicing handle a gas smell?

Dial 0800 111 999 first, with Highgate heat pump servicing pauses at once, and Highgate heat pump servicing returns once safe.

Talk to Heat Go

Ask about heat pump servicing in Highgate.

Share the number of zones and cylinders with Heat Go, and a pressure and vessel question list will be put together.

The quickest way to talk to a Gas Safe, WaterSafe and G3 certified team is to call +44 7551 336264.